Max tray size:
1 single rack 457×660 mm
Gas/electric models
Sanitary
Stainless steel.
Non corrosive steam system.
Specifications
Maximum Heat Capacity: See table
Temperature range: 95-572°F
Total shipping weight: 1980 lbs*
Minimum intake opening: 52”x57”
(one-piece shipment, without skid)
Minimum section tilt up height and recommended service height: 100”
Swing Diameter: 35.2”
Max load of rack lift and platform: 441 lbs
Steam Generation: 0.8 gals/20 sec at
482°F
*Final shipping
Weights will depend on the final order specifications.
Continuous product development is a Revent policy.Therefore, we reserve the right to change specifications and/or design without prior notice. Pictures or drawings may include product options.
Utility Requirements
Electrical
Electrical connection: 3 phase
Water and drain
Water Supply: ½” NPT 60-65 PSI cold
Drain: 1” NPT, optional connection to rear
Water quality ph 7.5-8.5, 4-7 gr/gals
Ventilation
Over Pressure Duct Through door to canopy
Oven Damper Exhaust ø 4”
Canopy Port 9.9” ø
Specifications
Maximum Heat Capacity: 37.5 kW
Temperature range: 95-572°F
Total shipping weight: 1980 lbs*
Standard shipping: Ships assembled in one piece, crated.
Minimum intake opening: 52”x57” (Assembled)
(one-piece shipment, without skid)
Minimum intake opening: 45”x 52” with Heat
section and bake chamber separated
Minimum section tilt up height and recommended service height: 100”
Swing Diameter: 35.2”
Max load of rack lift and platform: 441 lbs
Steam Generation: 0.8 gals/20 sec at
482°F
*Final shipping
Weights will depend on the final order specifications.
Continuous product development is a Revent
policy. Therefore, we reserve the right to change
specifications and/or design without prior notice.
Pictures or drawings may include product options.
Utility requirements
Electrical
Standard: 3PH208-220V+N 110A
Optional: 3PH440-480V 50A
+1PH/120V/60 Hz 15A
Contact factory for other power options
Water and Drain
Water Supply: ½”NPT ø 35-45 PSI, cold
Drain: 1” NPT
Water quality: pH 7-8.5
Hardness: 4-7 gr/gals.
Acceptable range for chloride concentration:
0-50 ppm
Ventilation
Direct Venting:
Canopy vent: 6” connection. 589 cfm
evacuation. Ducting and fan to be provided by
customer.
Venting via external exhaust hood:
Oven installed under an exhaust hood
designed to vent steam and vapor from the
oven. Type of products baked and local code
dictates if the exhaust hood should be a Type II
(normal baking) or Type I (grease laden vapor)
exhaust hood.)
Specifications
Maximum Heat Capacity: 170,000 btuh
Temperature range: 95-572°F
Total shipping weight: 1980 lbs*
Standard shipping: Ships assembled in one piece, crated.
Minimum intake opening: 52”x57”
(one-piece shipment without skid)
Minimum intake opening: 45”x52” with Heat
section and bake chamber separated
Minimum section tilt up height and recommended service height: 100”
Swing diameter: 35.2”
Max load of racklift and platform: 441 lbs
Steam Generation: 0.8 gals/20 sec at
482°F
*Final shipping
Weights will depend on the final order specifications.
Continuous product development is a Revent
policy. Therefore, we reserve the right to change
specifications and/or design without prior notice.
Pictures or drawings may include product options.
Utility requirements
Electrical
Standard: 3PH208-220V+N 9A
Optional: 3PH440-480V 6A
+1PH/120V/60 Hz 15A
Contact factory for other power options
Gas
Natural Gas and Liquid propane: 170,000 btuh @ 7-14” w.c ¾” drop to ½” NPT
Water and Drain
Water Supply: ½”NPT ø 35-45 PSI, cold
Drain: 1” NPT
Water quality: pH 7-8.5
Hardness: 4-7 gr/gals.
Acceptable range for chloride concentration: 0-50 ppm
Ventilation
Direct Venting:
Combustion flue: 4” connection. Draft diverter included. Ducting and fan to be provided by customer per local and state codes. Draft of 76 cfm is required (-0.3” to – 0.15” w.c)
Canopy vent: 6” connection. 589 cfm evacuation. Ducting and fan to be provided by customer.
Venting via external exhaust hood: Oven installed under an exhaust hood designed to vent by products of combustion and steam and vapor from the oven. Type of products baked and local code dictates if the exhaust hood should be a Type II (normal baking) or Type I (grease laden vapor) exhaust hood. Exhaust hood must be interlocked with oven.
The oven must be installed on a levelled
non-combustible floor. The oven may be
installed flush against a wall. Only the front
and top need to be left open for access.
The space on top of the oven must be well
ventlated and the temperature must not
exceed 50˚C/120˚F. This is to avoid damage to
electrical components.